Permit: T07CM01130

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T07CM01130

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/03/2009 BUILDING - FINAL Approved IVRS - Inspection :*
04/03/2009 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1. HANDRAILS BOTH SIDES OF STAIRS IBC 1009.10
2. ADA TOILET 16 TO 18" OFF FINISH WALL
3. NEED TRADE FINALS AND FIRE C OF O
4. BALLARDS FOR MECH. EQUIP.
06/10/2008 BUILDING - FINAL Denied PLACEMENT OF BUILDING ON SITE IS IN VIOLATION OF IBC SECTION 412.2.1. "EXTERIOR WALLS LOCATED LESS THAN 30 FET FROM PROPERTY LINES, LOT LINES OR A PUBLIC WAY SHALL HAVE A FIRE RESISTANCE RATING NOT LESS THAN 2 HOURS."

BUILDING OWNER MUST PROVIDE 2 HOUR EXTERIOR WALLS WHERE SAID WALLS ARE LESS THAN 30' FROM LEASED LOT LINE OR A CONTRACTUAL RESTRICTED COVENANT DECLARING A NO-BUILD EASEMENT.