Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/20/2009 | BUILDING - FINAL | Approved | ||
| 11/03/2008 | BUILDING - FINAL | Partial Approval | NEED FINAL APPROVED SITE PLAN. | |
| 06/24/2008 | BUILDING - FINAL | Partial Approval | 1) DOORS MAY REQUIRE NO MORE THAN 5 LBS OF FORCE TO OPEN. 2) PANIC HARDWARE OR THUMB ACTIVATED DEAD BOLT THAT OPENS WHEN TURNED 90 DEGREES REQUIRED AT REAR DOOR. 3) BREAK ROOM SINK TO BE NO MORE THAN 34" AFF. 4) VERTICAL GRAB BAR IN LOBBY RESTROOM TO BE MOUNTED 39' - 40" FROM REAR WALL. PROVIDE AIR BALANCE REPORT PROVIDE SEALED LETTER FROM D.O.R. FOR CHANGING PLUMBING FIXTURES. SHELL FINAL REQUIRED BEFORE BUILDING FINAL |
|
| 06/20/2008 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* KEYNOTE 6 PP A1 CALLS FOR "WATER FOUNTAIN @ ADA REQUIRED HEIGHT" ANSI REQUIRES BOTH HIGH & LOW FOUNTAIN CONFIGURATION. MOUNT A CUP DISPENSER WITH BOTTOM 34"-48" A.F.F. TO CORRECT |