Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
07/20/2009 BUILDING - FINAL Approved
11/03/2008 BUILDING - FINAL Partial Approval NEED FINAL APPROVED SITE PLAN.
06/24/2008 BUILDING - FINAL Partial Approval 1) DOORS MAY REQUIRE NO MORE THAN 5 LBS OF FORCE TO OPEN. 2) PANIC HARDWARE OR THUMB ACTIVATED DEAD BOLT THAT OPENS WHEN TURNED 90 DEGREES REQUIRED AT REAR DOOR. 3) BREAK ROOM SINK TO BE NO MORE THAN 34" AFF. 4) VERTICAL GRAB BAR IN LOBBY RESTROOM TO BE MOUNTED 39' - 40" FROM REAR WALL.

PROVIDE AIR BALANCE REPORT

PROVIDE SEALED LETTER FROM D.O.R. FOR CHANGING PLUMBING FIXTURES.

SHELL FINAL REQUIRED BEFORE BUILDING FINAL
06/20/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
KEYNOTE 6 PP A1 CALLS FOR "WATER FOUNTAIN @ ADA REQUIRED HEIGHT" ANSI REQUIRES BOTH HIGH & LOW FOUNTAIN CONFIGURATION. MOUNT A CUP DISPENSER WITH BOTTOM 34"-48" A.F.F. TO CORRECT