| 05/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL H.D. 2 X 4 AT GARAGE 2) A BOLT AT BOTTOM PLATE SPLICE N.W. CORNER FRONT OF GARAGE 3) SHEAR TRANSFER TO TRUSS NAILING 4" ON CENTER 4) KNOCKOUT ALL SHINERS AT SHEARWALL PANELS AND RENAIL 5) RAT RUNS MISSING ON B01 TRUSSES 6) MISSING NAILS AT SHEAR TRANSFER TO ROOF 7) NAILS MISSING VARIOUS LOCATIONS ON ROOF |
|
| 05/01/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |