Date Description Inspector Results Comments
06/05/2007 FRAMING Approved IVRS - Inspection :*
06/04/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WRONG NAILS IN HOLDOWNS
2) BLOCK REGISTER IN ENTRANCE FROM GARAGE
3) ANCHOR NEEDED IN SHORT SHEARWALL BETWEEN HOUSE AND GARAGE
4) FIREBLOCK ARCHWAY TO KITCHEN
5) DRAFT STOP UNDER 2ND FLOOR TUBS
6) WRONG NAILS IN RAFTER HANGERS UPSTAIRS GIRDER
7) NAIL OFF SOLE PLATES ON SHEARWALLS UPSTAIR TO PLAN
8) STURDY UP HALF HIGH WALL AT TOP OF STAIRS
9) BANG PLATES OVER ELECTRICAL BED #3 AND HALLWAY UPSTAIR
10) SHEARWALL MISSING UPSTAIRS BATHROOM
05/31/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
05/30/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
05/25/2007 FRAMING Not ready for Inspection IVRS - Inspection :*