Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01114
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRONG NAILS IN HOLDOWNS 2) BLOCK REGISTER IN ENTRANCE FROM GARAGE 3) ANCHOR NEEDED IN SHORT SHEARWALL BETWEEN HOUSE AND GARAGE 4) FIREBLOCK ARCHWAY TO KITCHEN 5) DRAFT STOP UNDER 2ND FLOOR TUBS 6) WRONG NAILS IN RAFTER HANGERS UPSTAIRS GIRDER 7) NAIL OFF SOLE PLATES ON SHEARWALLS UPSTAIR TO PLAN 8) STURDY UP HALF HIGH WALL AT TOP OF STAIRS 9) BANG PLATES OVER ELECTRICAL BED #3 AND HALLWAY UPSTAIR 10) SHEARWALL MISSING UPSTAIRS BATHROOM |
|
05/31/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
05/30/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
05/25/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |