Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM01111

Parcel: 141330270


Addresses:

10646 E GREEK DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01111

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/21/2007 FRAMING Approved IVRS - Inspection :*
05/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FURR OUT MASTER TOILET ROOM WALL AND NAIL PROTECT
2) USE PROPER NAILS IN FHA STRAP MASTER CLOSET
3) SHEAR PANEL NEEDED MASTER BEDROOM CLOSET
4) HCC4 NEEDED MASTER BEDROOM ? WALL
5) FINISH STUCCO BACK SIDE
6) TAPE HOLE IN PAPER SOUTH WALL MASTER BEDROOM
7) MINIMUM 12" CLEARANCE FOR WATER LINES TO RECESSED CANS IN KITCHEN
8) BOND GAS LINE
9) DRAIN A/C CONDENSATE LINE TO EXTERIOR
05/17/2007 FRAMING Not ready for Inspection IVRS - Inspection :*