Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01109
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/10/2007 | FRAMING | Approved | IVRS - Inspection :* | |
07/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PEX PLUMBING MUST BE 6" FROM B-VENT |
|
07/05/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* ITEMS 6, 7, 8, 9, 10 FROM 7/2/07 NOT COMPLIED WITH |
|
07/02/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OUTSIDE HOSE BIBS REQUIRE ANTI SIPHON VALVES 2) STAIRS HAVE MORE THAN 3/8" DIFFERENCE IN RISE ANSD EXCEED 7 3/4" 3) FIRE BLOCK STAIRS 4) CS 16 STRAPS MISSING AT STAIRS 5) FIRESTOP FLOOR PENETRATIONS 6) 12/D6 NOT COMPLIED WITH AT GARAGE SHEAR 7) W/H B-VENT MUST RISE AT 30 DEGREE MINIMUM 8) 1" CLEARANCE REQUIRED TO COMBUSTIBLES AT B-VENT 9) PEX MUST BE 6" FRON B-VENT 10) PROVIDE MUD RING FOR UFER 11) STOPPED INSPECTION-TOO MANY ITEMS |
|
06/21/2007 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES 2) NO GAS TEST 3) NO DWV TEST 4) STAIRS HAVE MORE THAN 3/8" DIFFERENCE IN RISE 5) STOPPED INSPECTION-TOO MANY ITEMS 6) HOUSE NOT READY |