Permit: T07CM01106

Parcel: 141097210

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01106

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/11/2007 FRAMING Approved IVRS - Inspection :*
06/07/2007 FRAMING Partial Approval IVRS - Inspection :*
1) HORIZONTAL RUN OF B-VENT MUST HAVE A MINIMUM OF 30 DEGREE RISE
06/06/2007 FRAMING Partial Approval IVRS - Inspection :*
1) ITEMS 3, 4 AND 7 FROM 6/4/07 NOT DONE
06/04/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATHE NOT COMPLETE
2) NO GAS BOND
3) HORIZONTAL RUN OF GAS B-VENT MUST BE MINIMUM 30 DEGREE PITCH
4) PROVIDE INSULATION SHIELD FOR B-VENT
5) FIRESTOP N.W. BEDROOM FROM GARAGE CEILING
6) WIRING CUT-REPLACE
7) REVERSE PITCH AT A/C CONDENSATE