Inspection Status: Partial Approval
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXCEPT BREAK THROUGH |
|
| 02/11/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXCEPT ENT. CENTER OK TO INSULATE AND SHEETROCK OTHER 2) ROMEX INSULATION MUST PENETRATE BOX MINIMUM 1/4" CAN LIGHTS ENT. CENTER 3) FIRE STOP ENT. CENTER AT 4 CHASES IN BETWEEN BOXES WITH MINIMUM 3/4" PLYWOOD |
|
| 11/26/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE NOTES 3, 4 & 5 FROM PREVIOUS INSPECTIONS 10/22 2) ALL WIRING TO CAN LIGHTS IN APPROVED BOXES SEALED 3) NAIL PROTECT ANY ROMEX WITHIN 1 1/4" STUD OR RAFTER EDGE 4) FIREBLOCK ENTERTAINMENT CENTER 5) MISSING OUTLET PONY WALL EAST |
|
| 10/29/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH #3, 4 & 5 BELOW 2) FIRE BLOCK MISSING AT INTERIOR BEARING WALL AT CEILING JOIST 3) ROOF NOT FRAMED PER PLAN, HIP RAFTERS SHALL BE DESIGNED AS BEAMS. SUBMIT AS BUILT DRAWING TO D.S.D. FOR APPROVAL 4) DO NOT MIX 12-2 WITH 14-2 WIRES 5) CHECK LISTING ON CAN LIGHTS FOR CLEARANCES REQUIRED FROM COMBUSTIBLES. HAVE LISTING ON SITE |
|
| 10/22/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 X 2 FURR OUT PLATES MUST BE TREATED 2) PROVIDE CONTINOUS TIE DOWN TV EAST WALL TOP PLATE TO 2 X6 HEADER 3) FIRESTOP ENTERTAINMENT 4) MISSING OUTLET PONY WALL 5) NAIL PROTECT ROMEX FURROUT 6) MISSING SMOKE DETECTOR GUEST BEDROOM 7) RE-ROUTE CAN LIGHT ROMEX ENT. CENTER 8) REPLACE FAN BOXES WITH RATED BOXES 9) LIGHT IN GUEST BEDROOM CLOSET WILL BE TO CLOSE TO SHELVING |
|
| 10/03/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES AND CALL IN INTERMEDIATES TOGETHER |
|
| 09/24/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES 2) FIRESTOP ENTERTAINMENT CENTER |
|
| 09/19/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ANSWER FRONT DOOR 12:00PM |