Permit: T07CM01084

Parcel: 141312760

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM01084

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/03/2007 EXT METAL CLIPS/EXT SHEATHING Approved
05/14/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO LATHE
2) TRUSS REPAIR FROM ORIGINAL INSP
05/11/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) WIND BRACE 1ST FLOOR NORTH CORNER
2) MISSING HIP HANGERS, 2ND FLOOR REAR
3) 5'-0" CS STRAP TOP CHORD TO TOP CHORD LIVING ROOM TO DINING, EVERY OTHER HOLE 8D'S
4) REPLACE ALL HANGER NAILS PER CORRECT SIZE
5) REPLACE ALL P.A. STRAPS PER CORRECT SIZE
6) CHANGE OUT WINDOW HEADER TO 3 2 X 10'S WITH 3 2 X 6 CRIPPLE WEST/BED 1ST FLOOR
7) NEED SHEAR TRANSFER FOR NORTH GARGAE R F 3 G (NOT A DRAG TRUSS)
8) TRUSSES CUT AT KITCHEN/DINING VERT MEMBERS 8 TOTAL