Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM01083

Parcel: 141312890

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM01083

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/03/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/02/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) FRONT 1/2 BATH NO HANGER AT END TRUSS, LEDGER NOT TIGHT TO WALL
2) CHECK LAYOUT OF TRUSSES OVER DRY BAR
3) NEED WIND BRACE FRONT GARAGE EAST WALL
4) DECK AT REAR (WALKING) NOT NAILED/SCREWED
5) STRAIGHTEN CRIPPLES 2ND FLOOR BATH AT DBL 2 X 6 HEADER
6) LAMINATED BEAM 2ND FLOOR-ROOF BLOCKED UNDER SUPPORT BETWEEN FLOORS EACH END
7) 5'-0" CS16 STRAP AT FRONT MIDDLE ROOF