Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01083
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) FRONT 1/2 BATH NO HANGER AT END TRUSS, LEDGER NOT TIGHT TO WALL 2) CHECK LAYOUT OF TRUSSES OVER DRY BAR 3) NEED WIND BRACE FRONT GARAGE EAST WALL 4) DECK AT REAR (WALKING) NOT NAILED/SCREWED 5) STRAIGHTEN CRIPPLES 2ND FLOOR BATH AT DBL 2 X 6 HEADER 6) LAMINATED BEAM 2ND FLOOR-ROOF BLOCKED UNDER SUPPORT BETWEEN FLOORS EACH END 7) 5'-0" CS16 STRAP AT FRONT MIDDLE ROOF |