Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01082
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED TRUSS REPAIR DETAIL |
|
| 04/30/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ITEMS ABOVE NOT DONE #2, TRUSS REPAIR PAPERWORK 2) STAPLES NOT LONG ENOUGH GAP BETWEEN MEMEBERS USE 8D'S-USE 8D'S AT SHEAR BLOCK PANEL TO ROOF |
|
| 04/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING WIND BRACING REAR WALL 2ND FLOOR 2) TRUSSES CUT VERT. MEMBER LIVING ROOM AT UPPER BEARING CHECK WITH TRUSS MANUFACTURER 3) NAIL OFF JOINTS ROOF SHEATHING ON WEST SHED ROOF, MARKED IN BLACK 3" ON CENTER 4) NAIL BLOCKS TO ROOF 89/SD3, ALSO ABOVE, BAR 90/SD3 INTER. BEARING LIVING ROOM 5) 1A/SD2 PLYWOOD ENDS OF TRUSSES AT GARAGE OPENING 6) AT FLOORS 2/SD2 BLKS, ARE TO BE USED AS DRYWALL NAILERS 7) G-1 12'-0" PANEL EAST FRONT GARAGE NEED BELLY BAND, TRANSFER 16'-0" PANEL REAR 8) A.35 24" ON CENTER FLOOR TRUSS TO SHEAR INTER GARAGE WALL/KIT SAME WALL MARKED ON FLOOR KIT |