Permit: T07CM01082

Parcel: 141313300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM01082

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/04/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/02/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED TRUSS REPAIR DETAIL
04/30/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ITEMS ABOVE NOT DONE #2, TRUSS REPAIR PAPERWORK
2) STAPLES NOT LONG ENOUGH GAP BETWEEN MEMEBERS USE 8D'S-USE 8D'S AT SHEAR BLOCK PANEL TO ROOF
04/26/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING WIND BRACING REAR WALL 2ND FLOOR
2) TRUSSES CUT VERT. MEMBER LIVING ROOM AT UPPER BEARING CHECK WITH TRUSS MANUFACTURER
3) NAIL OFF JOINTS ROOF SHEATHING ON WEST SHED ROOF, MARKED IN BLACK 3" ON CENTER
4) NAIL BLOCKS TO ROOF 89/SD3, ALSO ABOVE, BAR 90/SD3 INTER. BEARING LIVING ROOM
5) 1A/SD2 PLYWOOD ENDS OF TRUSSES AT GARAGE OPENING
6) AT FLOORS 2/SD2 BLKS, ARE TO BE USED AS DRYWALL NAILERS
7) G-1 12'-0" PANEL EAST FRONT GARAGE NEED BELLY BAND, TRANSFER 16'-0" PANEL REAR
8) A.35 24" ON CENTER FLOOR TRUSS TO SHEAR INTER GARAGE WALL/KIT SAME WALL MARKED ON FLOOR KIT