Inspection History: FRAMING

Date Description Inspector Results Comments
07/10/2007 FRAMING Approved IVRS - Inspection :*
1) OK TO TAPE LAUNDRY
06/28/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED SOME CAULK
2) RE-DO LOW PRESSURE
3) SUPPORT ABS VENT 90 DEGREE AT LAUNDRY AND MASTER LAV
4) FIREBLOCK ALL FURRED WALLS AND LINEN CLOSET CHASES
5) MOVE PEX 12" FROM CANS
6) ADD OUTLET ON NORTH LIVING ROOM WALL AND S.W. CORNER OF S.W. BED AND N.E. CORNER OF N.W. BED
7) BANG MASTER SHOWER ABS