Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00995

Parcel: 114600820

Inspection Status: Approved

Inspection History: PLUMBING - ROOF DRAINS

Permit Number - T07CM00995

Inspection Description - PLUMBING - ROOF DRAINS

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2007 PLUMBING - ROOF DRAINS Approved IVRS - Inspection :*
08/14/2007 PLUMBING - ROOF DRAINS Partial Approval IVRS - Inspection :*
3" PIPING IN CONCRETE COL OK TO COVER
TEST AFTER INSTALLING SWEEPS
07/26/2007 PLUMBING - ROOF DRAINS Not ready for Inspection IVRS - Inspection :*
- PIPING COVERED WITHOUT INSPECTION.
- PLAN CALLS FOR 4" RAIN DRAIN & OVERFLOW
- PROVIDE ACCESS TO PIPING & PROVIDE LONG RADIUS DRAINAGE FITTINGS.
- PROVIDE STAMPED SEALED LETTER FROM ENGINEER FOR OK OF 3" FROM PLAN OF 4" RD & OFRD