Permit: T07CM00987

Parcel: 10409002D


Addresses:

475 W WETMORE RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07CM00987

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/14/2007 PLUMBING - FINAL Approved
06/08/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CRITICAL LEVEL OF FLUSH-O-METER SHALL BE 6" ABOVE THE HIGHEST PART OF URINAL. (603.4.1)
06/06/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. FINISH URINAL
2. OK TO RESET OFFSET WATER CLOSET
05/31/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. MENS HC WATER CLOSET DOES NOT HAVE CLEARANCES
2. HAMMER ARRESTORS, TRAP PRIMER, AIR ADMITTANCE VALVE TO BE ACCESSIBLE.

DID NOT GO ONTO ROOF
05/24/2007 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1. FIXTURES INSTALLED IN ALL AREAS EXCEPT IN MENS ONLY AREA. PLUMBERS STILL WORKING.
2. NO SERIOUS SAFETY HAZARDS EXIST IN PLUMBING.
I HAVE NO PROBLEM WITH TCO
3. FIXTURES NOT INSTALLED SHALL HAVE PIPING CAPPED OR PLUGGED.
4. URINALS REQUIRE 3/4" WATER SUPPLY
5. EXISTING HB ON ROOF REQUIRES VAC BREAKER VENT THROUGH ROOF REQUIRE PAINT.
6. ROOF DRAINS REQUIRE STRAINERS.
05/23/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*