Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00987

Parcel: 10409002D


Addresses:

475 W WETMORE RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM00987

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/19/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP SEE 706.4 2003 UPC

WHERE A VENT CONNECTS TO A HORIZONTAL DRAIN, IT SHALL HAVE ITS INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE DOWNSTREAM OF THE TRAP BEING SERVED 905.2 UPC

REINSPECTED 2:00 PM
1. CORRECTIONS MADE OK
2. OK TO COVER
3. OK FOR CONCRETE
04/18/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. NOT INSTALLED PER PLAN
NO REDLINES ON SITE
INSTALLATION DOES NOT MEET CODE
2. WHERE A VENT CONNECTS TO A HORIZONTAL DRAIN IT SHALL HAVE ITS INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE DOWNSTREAM OF THE TRAP BEING SERVED.
3. MAY NOT INTERMINGLE MATERIAL TYPES
4. MAY NOT CONNECT CONDENSATE WASTE TO SANITARY SEWER.
5. PIPE NOT COMPLETELY WRAPPED IN FOOTING
6. NO SOFT SOLDER BELOW THE FLOOR
7. ALL FIXTURES TO BE VENTED
HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP