Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00973
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO REVISE PLANS WITH CITY ON PORCH CHANGE FROM ROUGH SAWN TO STUCCO WITH COLUMNS |
|
08/21/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H2.5 CLIPS MISSING PER 9A/DT1 |
|
08/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ALL BUT PORCH |
|
08/08/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWO HOLDOWNS IN REAR OF HOUSE IN WRONG LOCATIONS. PROVIDE ENGINEERS APPROVED REPAIR 2) TRUSSES A03C, A03A, A02 AND A01 HAVE BEEN NOTCHED FOR LOOKOUT BLOCKS YOU MUST PROVIDE CITY APPROVED TRUSS ENGINEERS REPAIR DOCUMENT FOR EACH TRUSS ON EACH HOUSE BY ADDRESS 3) TRUSS REPAIR NOT MADE PER UN APPROVED REPAIR DOCUMENTS 4) 2/DT1 BLOCK PANELS MUST EXTEND TO ROOF SHEATHING 5) SHIM 3 POINT BEARING TRUSSES FOR FALL BEARING 6) TRUSSES NOT CLIPPED PER 2/DT1 7) OSB ROOF SHEATHING MUST SPAN 3 TRUSSES, 2 BAYS REPLACE 3 LOCATIONS 8) SOME ROOF PANELS NOT NAILED ON ENDS |