Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM00969
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/07/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/04/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED ADDITIONAL NAIL PLATES LOW & HIGH VOLTAGE 2. HAVE OVERFILLED J-BOXES 3. MISSING GFI UPSTAIRS BATHROOM 4. LOW VOLTAGE WIRING TO CONNECT TO METAL BOXES USING PROPER CONNECTOR 5. GROUND ALL METAL BOXES CONTAINING 120V CKT 6. HAVE ROMEX OUT OF CEILING DOWNSTAIRS HALL ABOVE BEDROOM CLOSET 7. ROMEX, LOW VOLTAGE WIRING TO BE PROPERLY SUPPORTED IN CEILING AREAS, NOT JUST STRETCHED ACROSS 8. ALL GROUND CRIMP SLEEVES REQUIRE USE OF PROPER TOOL 9. WHERE IS ATTIC ACCESS? ROMEX TO BE PROTECTED WITHIN 6' OF ATTIC ACCESS 10. PROVIDE INSTALL MANUAL FOR CENTRAL VAC SYSTEM SO I CAN VERIFY INSTALLATION PER MANUF. INSTRUCTIONS. |
|
08/16/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK COMMON WALL COVER |
|
08/14/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR COMMON WALL ONLY 1. HAVE PLENTY OF NAIL PLATES, EVEN WHERE NOT NEEDED BUT YOU MISSED TWO @ KITCHEN CORNER FOR MICROWAVE HOMERUN AND 14-2 ABOVE IT. ALSO, AT END OF WALL IN LIVING ROOM BY BACK PORCH |
|
08/01/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. A PROPER CRIMPING TOOL TO BE USED FOR CRIMP SLEEVES NEC 110.3 B 2. CONDUCTORS, INCLUDING ALL EQUIPMENT GROUNDING CONDUCTORS ARE TO HAVE ENOUGH SLACK TO EXTEND FROM THE BOX A MINIMUM OF 6" 3. YOU ARE MISSING A HOMERUN TO YOUR KITCHEN COUNTER RECEPTACLES AND STAPLE ROMEX INTO BOXES. WHERE IS MICROWAVE ON PLAN? CHECK ALL HOMERUNS TO MAKE SURE THERE 4. PROVIDE ADDITIONAL NAIL PLATES WHERE NEEDED 5. MISSING LIGHT FIXTURES/BOXES, MISSING BATH MUD RING PARTIAL INSPECTION - GO THROUGH UNIT BEFORE YOU CALL IN |