Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM00966
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
08/16/2007 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
08/14/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPAIR STUCCO BACK PORCH 2) NO DEAD FRONT COVER EAST A/C DISCONNECT 3) TERMINATE WIRE SECURITY PANEL 4) NEED VACUUM BREAKER HOSE BIB AT ENTRANCE PIPE 5) TRACER WIRE FOR SEWER MUST BE ACCESSIBLE 6) SECURE A/C WHIPS WITHIN 12" OF DISCONNECT 7) NEED SECONDARY CONDENSATE DRAINS OR CUT OFF SWITCHES ON BOTH FURNACES 8) SECURE DISHWASHER DRAIN HOSE TO HIGH POINT UNDER COUNTER 9) NEED GAS SHUT OFF FOR FIREPLACE THAT IS READILY ACCESSIBLE AND SERVES NO OTHER APPLIANCE |