Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00966
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/18/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED RETRO H/D FROM CLIP NOTES 2) FIRE BLOCK AT TOP PLATE MAIN PANEL 3) BLOCK REGISTER BOX NORTH HALL 4) SHIM TRUSSES AS NECESSARY AT 3 PT BEARING 5) FIREBLOCK KITCHEN HOOD 6) FIRESTOP CHIMNEY CHASE 7) BLOCK REGISTER MASTER HALL 8) FIRE BLOCK MASTER BATH 9) CONDUIT OUT OF WALL N.W. BEDROOM 10) REMOUNT CAN LIGHT MASTER HALL 11) STAPLE WIRE DINING CEILING 12) INSTALL VACUUM BREKAERS ON HOSE BIBS 13) SUPPLY AND DWV OK 14) STRAP CHIMNEY AT LEAST 3 PLACES |