Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/10/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
09/08/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. FINISH INSULATING RETURN PIPING AT W.H
2. 2 COMPARTMENTS OF 3-COMP SINK DRAIN
3. ADD CLEANOUTS AT TRAP ARMS OVER 90 DEG.
4. HOOK UP ALL EQUIPMENT MAKE ALL CONNECTIONS
5. FINISH HOOKING UP JANITORS SINK AT G.T
09/02/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ICE MAKER/STORAGE BIN DRAINS MAY NOT BE COMBINED
2. RP DEVICE MAY NOT BE REDUCED
3. MINIMUM 1" AIR GAP
4. GREATER THAN FIVE FEET IW PIPING TO BE DIRECTLY TRAPPED
5. ALL PIPING TO BE SUPPORTED INSTALLED IN A WORKMANSHIP LIKE MANNER
6. 2-COMPS OF 3-COMP SINK TO BE DIRECTLY CONNECTED
7. MOVEABLE GAS APPLIANCES TO HAVE QUICK DISCONNECT AND CABLE RESTRAINT
8. TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEG. W/O ADDING A CLEANOUT
9. IW PIPING TO BE APPROVED MATERIAL AIR GAP ENFORCED
10. H.C BOWL TO BE 17 1/2" OPEN FRONT SEATS
11. CLEAN BACTERIA REPORT
12. CERTIFICATION OF BACKFLOW DEVICES