Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00952

Parcel: 141096850

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00952

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/10/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/09/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DIAGONAL BRACES REQUIRE 2-16D NAILS ON ENDS
2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE SURFACES
3) STRAP NON OVERLAPPING DBL TOP PLATES