Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM00949
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/15/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
08/13/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : 1) 15" CLEARANCE REQUIRED BETWEEN CENTER LINE OF MASTER TOILET AND CABINET PRESENTLY ONLY 10 1/2" EXISTING 2) WATER HEATER SPARK SHIELD MISSING |
|
08/08/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO GAS VENT WEATHER CAPS 2) PAINT PVC IRIGATION LINE 3) MAXIMUM ALLOWED PVC EXPOSED RISER 24"-USE METAL 4) WATER HEATER MUST BEAR ON NON COMBUSTIBLE SURFACE 5) OPEN GROUND IN S.E. BEDROOM 6) DISHWASHER DRAIN NOT INSTALLED 7) STOPPED INSPECTION-TOO MANY ITEMS |