Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00949
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/16/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/12/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 8060 CRIPPLE STUDS MUST BE CLIPPED TO HEADER ALSO 3030 ON EAST SIDE 4030 ALSO 2) F7 TRUSSES MISSING TRUSS BRACE ABOVE DEAD WOOD 3) STRAP SPLICE AT 2 X 4 AND 2 X 6 TOP PLATE BY STAIR 4) KNEE BRACES MISSING SEE 2/D-2 |