Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM00949

Parcel: 141096830

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/16/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/12/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 8060 CRIPPLE STUDS MUST BE CLIPPED TO HEADER ALSO 3030 ON EAST SIDE 4030 ALSO
2) F7 TRUSSES MISSING TRUSS BRACE ABOVE DEAD WOOD
3) STRAP SPLICE AT 2 X 4 AND 2 X 6 TOP PLATE BY STAIR
4) KNEE BRACES MISSING SEE 2/D-2