Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/07/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* VENT FOR RESTROOM IS REQUIRED TO BE 2" MINIMUM THRU ROOF, EXPOSE THIS CONNECTION AND TERMINATE PROPERLY |
|
| 12/06/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. EAST UNIT ON ROOFTOP REQUIRES CORRECT BTU RATED FLEX FOR GAS SUPPLY 2. VENT FROM WEST RESTROOM TO BE TERMINATED PROPERLY 3. REPAIR LEAK ON GAS PIPING |
|
| 12/03/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. COMPLETE PIPING TO ROOFTOP UNITS FOR GAS SYSTEM AND RETEST 2. PUBLIC USE LAVS REQUIRE A MEANS BESIDES THE WATER HEATER TO CONTROL HOT WATER TEMPERATURE NOT TO EXCEED 110 DEG. |