Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/09/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS 2) COMPLETE GARAGE DOOR 3) COMPLETE GRADING 4" FROM WEEP AWAY FROM BLDG 4) CLAMP GAS BOND 5) SECURE PANEL RISER AT BASE 6) PROVIDE 30" CLEARANCE CONDENSOR DISCONNECT 7) PAINT CONDENSATE 90 8) BUBBLE COVER EXTERIOR GFCI'S NOT UNDER ROOF 9) LOWER CLEANOUTS TO GRADE 10) INSTALL DISHWASHER AND STOVE 11) PROVIDE PROOF OF REAR PORCH SLAB INSPECTION PER DETAIL C/S2 12) GFCI PROTECT GARAGE OUTLETS 13) SEAL GARAGE LID AT EQUIPMENT |
|
| 03/19/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |