Permit: T07CM00869

Parcel: 141096810

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/27/2007 FRAMING Approved IVRS - Inspection :*
04/26/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WRONG HOLDOWN AND BOLTS
04/25/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OK TO INSULATE
2) GROUND METAL ELECTRIC BOXES
3) KITCHEN SHEARWALL HOLDOWN NOT ON SHEARWALL