Permit: T07CM00854

Parcel: 13613027F

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00854

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/25/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/18/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN
2) USE NAILS OR SCREWS LISTED FOR USE ON JOIST HANGERS
3) JOIST HANGER NAILS 1 1/2" LONG
4) ANGLED NAILS SHOULD BE 16 PENNY
5) CHECK AT INTERMEDIATE INSPECTIONS