Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM00837
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/15/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNISEX B CLOSET FLANGE OK |
|
10/11/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. UNISEX RESTROOM NORTH SIDE OF DORMITORY IN WALL OK 2. CALL BACK FOR CLOSET FLANGE INSPECTION |
|
08/21/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
08/20/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) MENS TOILET A WASTE AND VENT AND WATER PIPING OK |
|
08/17/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* TOILET A MENS RESTROOM, LAV DRAIN ARM REQUIRED TO BE APPROVED 1 1/2 DRAINAGE MATERIAL, 2" DRAIN ARM REQUIRES 2" P-TRAP, 2" P-TRAP CANNOT BE USED ON 1 1/4" TAILPIECE DEVICE. |
|
07/10/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ROOM #1 OK FOR PLUMBING FINAL ROOM #14 OK WASTE & VENT & WATER PIPING |
|
06/21/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST LAV SOUTHEAST ROOM 1 OK CLOSET FLANGE OK 1. PROVIDE SUPPORTS FOR RE-ROUTE OF CONDENSATE DRAIN |
|
06/15/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) WATER PIPING TO NEW LAV LOCATION SOUTH EAST DORM AND CAPS FOR WATER AT OLD LOCATION OK 2) STOOL SHAL HAVE CLOSET FLANGE INSPECTION PRIOR TO SETTING STOOL 3) CONDENSATE TO BE TERMINATED TO NEW LAV 4) WATER TEST LAV DRAINAGE AND VENT-SHALL CAP OLD LAV DRAIN |