Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/16/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED TRUSS REPAIR DETAIL 2) OK TO INSULATE |
|
| 05/14/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED DWV TESTED 2) MISSING FIREBLOCKS AT SEVERAL SOFFITS SEE MARKS ON FLOOR 3) OVER NOTCHED DIVERTER VALVE STUD 4) MISSING BLOCKS AT TUB SIDES 5) SHIM AT STUDS TO GLU LAM MASTER BED, BAY WINDOW 6) FRONT PORCH END 2 X 4 IN LID IS BOWED 7) AT HALL BATH DRIVE NAILS HOME AT H.D. 8) USE 16D SINKERS AT SKED NAIL HOLE HANGER TO GIRDER (HUS26) 9) BOWED STUD MASTER BATH 10) TRUSS A17A, A16, BEARING PT NOT BELOW VERT MEMBER ON TRUSS |