Permit: T07CM00834

Parcel: 141313060

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM00834

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/17/2007 FRAMING Approved IVRS - Inspection :*
05/16/2007 FRAMING Partial Approval IVRS - Inspection :*
1) NEED TRUSS REPAIR DETAIL
2) OK TO INSULATE
05/14/2007 FRAMING Partial Approval IVRS - Inspection :*
1) NEED DWV TESTED
2) MISSING FIREBLOCKS AT SEVERAL SOFFITS SEE MARKS ON FLOOR
3) OVER NOTCHED DIVERTER VALVE STUD
4) MISSING BLOCKS AT TUB SIDES
5) SHIM AT STUDS TO GLU LAM MASTER BED, BAY WINDOW
6) FRONT PORCH END 2 X 4 IN LID IS BOWED
7) AT HALL BATH DRIVE NAILS HOME AT H.D.
8) USE 16D SINKERS AT SKED NAIL HOLE HANGER TO GIRDER (HUS26)
9) BOWED STUD MASTER BATH
10) TRUSS A17A, A16, BEARING PT NOT BELOW VERT MEMBER ON TRUSS