Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00834

Parcel: 141313060

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM00834

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/17/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/16/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT DWV PIPES AT EXTERIOR BOTTOM PLATES
2) FINISH NAILING RSP4 TO DBL PLATE NORTH WEST CORNER
3) NEED LADDER TO ACCESS ROOF
4) STHD 8 NAILED AT WEST SIDE EXTERIOR BATHROOM AND EXTERIOR WALL
5) COIL STRAP NON-OVERLAPPING DBL PLATES AT MASTER BEDROOM 45 DEGREE BUMPOUT BAY