Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM00805

Parcel: 141096020

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
07/16/2007 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*