Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00790
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/17/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED NAILING ON PANEL AT KITCHEN 2) REPLACE SHEAR PANEL WITH BIG HOLE CUT OUT S.W. CORNER 3) NO LADDER FOR ROOF ACCESS |
|
04/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT GARAGE EACH SIDE SHEAR NAILING 3" ON CENTER 2) MISSED 4' PANEL REAR SOUTH 3) WRONG SIZE NAILS IN P.A. 22 REAR 16D REQUIRED 4) NAIL ALL STUDS ATTACHED TO P.A.'S TO OSB 5) EXTEND SHEAR WALL GARAGE TO HOUSE UP TO DBL TOP PLATE OF RAKE WALL, FROM OUTSIDE TO DOOR 6) SEE BLACK MARKS ON ROOF |