Permit: T07CM00784

Parcel: 12314126D


Addresses:

711 E LESTER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/04/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
2. INSTALLED PER REDLINES OK SUBJECT TO ARCHITECT/OWNER APPROVED OF VANITY LAVS
3. PLUMBING FINAL OK
11/29/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
SEE 409.1 2003 UPC ELONGATED
409.22 2003 UPC SEATS OPEN FRONT

- WATER COOLER NOT INSTALLED PER PLAN -
COVERED W/O INSPECTION
- ABS NOT PERMITTED IN EXTERIOR LOCATION
ABOVE GRADE
- SANTEE NOT PERMITTED ON ITS BACK
- PLAN SHOWS REVENT - NOT AAV
- TEMPERING VALVE NOT ACCESSIBLE FOR SERVICING
- EXPANSION TANK NOT SUPPORTED
- HOT PIPING NOT INSULATED
- PAN DRAIN MAY NOT BE REDUCED
- MAY NOT BE A COMPLETE LIST