Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) OK TO COVER ALL AREAS |
|
| 09/26/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. CLOSET FLANGES TO BE SCREWED TO THE FLOOR 2. FHA STRAPS/NAIL GUARDS WITHIN 1 1/4" OF STUD FACE 3. USE APPROVED STRAPS |
|
| 09/25/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SEE 609.1 2003 UPC "ALL CHANGES OF DIRECTION SHALL BE THROUGH APPROVED FITTINGS..." 2. 2003 IECC REQUIRES EIGHT FEET OF INSULATION ON HOT & COLD WATER INLETS AT WATER HEATER. NO PROVISION MADE FOR INSULATION 3. NEED TO SEE CLOSET FLANGES 4. SUPPORT OVERHEAD PIPING WITH APPROVED STRAPS DWV WATER TEST OK |
|
| 09/21/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - PROVIDE TEST ON ALL PIPING - SUPPORT & SECURE ALL OVERHEAD PIPING AT CORRECT INTERVALS. |