Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/30/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE APPROVED P-TRAP ON OUTSIDE WATER COOLERS AND WATER SUPPLY 2. COMPLETE LIST FROM 6/24/08 3. ADD SUPPORTS TO MOP SINK |
|
| 06/24/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE APPROVED SUPPORT ON DRAIN PIPING FOR KITCHEN SINKS 2. PROVIDE APPROVED SUPPORT FOR EXPANSION TANK AT WATER HEATER 3. MAKE ALL OUTSIDE CLEANOUTS WATER & GAS TIGHT 4. SEAL ALL HOLES IN WALLS |
|
| 05/27/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE SUPPORT ON DRAIN PIPING FROM SINKS IN KITCHEN 2. PROVIDE CLEAN WATER REPORT (UPC 609.19) 3. PROVIDE APPROVED SCREWS FOR CLEANOUT 4. HARD PIPE T&P AT WATER HEATER 5. INSTALL EXPANSION TANK AT WATER HEATER 6. PROVIDE MIXING VALVES AT ALL LAVS (UPC 414.1) 7. PROVIDE LADDER FOR ROOF INSPECTION 8. LIST MAY NOT BE COMPLETE |