07/02/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
06/30/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE APPROVED P-TRAP ON OUTSIDE WATER COOLERS AND WATER SUPPLY
2. COMPLETE LIST FROM 6/24/08
3. ADD SUPPORTS TO MOP SINK
06/24/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE APPROVED SUPPORT ON DRAIN PIPING FOR KITCHEN SINKS
2. PROVIDE APPROVED SUPPORT FOR EXPANSION TANK AT WATER HEATER
3. MAKE ALL OUTSIDE CLEANOUTS WATER & GAS TIGHT
4. SEAL ALL HOLES IN WALLS
05/27/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE SUPPORT ON DRAIN PIPING FROM SINKS IN KITCHEN
2. PROVIDE CLEAN WATER REPORT (UPC 609.19)
3. PROVIDE APPROVED SCREWS FOR CLEANOUT
4. HARD PIPE T&P AT WATER HEATER
5. INSTALL EXPANSION TANK AT WATER HEATER
6. PROVIDE MIXING VALVES AT ALL LAVS (UPC 414.1)
7. PROVIDE LADDER FOR ROOF INSPECTION
8. LIST MAY NOT BE COMPLETE