Permit: T07CM00782

Parcel: 12103074A


Addresses:

5801 E PIMA ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/09/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/06/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
3-COMP SINK WALL RESTROOM LAV DRAINAGE TO BE 1 1/2 NOT TO EXCEED 42" DRAIN ARM

OTHER RESTROOM LAV DRAINAGE TO HAVE MINIMUM FALL 1/4" PER FOOT AND BE 1 1/2 DRAIN ARM. PERM CAPS REQUIRED ON DEMO AS PER 8/3/07 INSP. DOUBLE VENT AT 3-COMP SINK AREA IS FOR ? AND DOES NOT MEET 2003 UPC REQUIREMENTS.

OK TO COVER NORTH RESTROOMS, P-3 SINK
P-4 MOP SINK FOR PLUMBING
08/03/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
- USE 03050 FOR GAS PIPE INSPECTIONS
- GAS PIPING NOT SIZED PER PLAN. ALSO, 3 1/2" REQUIRED ABV ROOF.
- WATER PIPING NOT SIZED PER PLAN, SEE FIXTURE SCHEDULE.
- WASTE & VENT NOT PER PLAN. REDLINE PLAN TO CONTINUE.
- PLAN REVISION REQUIRED FOR GW, DF, ABS AND AAV AT P-3
- CORRECT SLOPE AT TIE IN
- CORRECT UNVENTED FS
- PROPERLY INSTALL DRAINAGE FITTINGS
- PROPERLY INSTALL TRAP ARMS
- PERM CAPS REQUIRED ON DEMO
- BACKFLOW PREVENTER REQUIRED FOR IRRIGATION