Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM00779
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2007 | FRAMING | Approved | IVRS - Inspection :* | |
05/23/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
05/21/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE H20 SERVICE LINE AND 11/4" GS AT METER LOCATION 2) CHECK LEAK 2" ABS (VERT DRAIN) GARAGE AT BOTTOM/TOP PLATE 3) SECURE GAS LINE AT DRYER 4) LOW H20 PRESSURE POTABLE H20, WAS H20 YARD LINE CUT ? 5) TWO OVER NOTCHED DIVERTER STUDS 6) LEAVE TRUSS REPAIR DETAIL IN PERMIT BAG, N.E. BEDROOM, ABOVE STAIR 7) 2ND FLOOR, NAIL BOTTOM PLATES SHEARWALLS PER PLAN 8) X BRACE TRUSS 2ND FLOOR ROOF REAR 9) PT LOAD GIRDER ROOF BRING DOWN TO CONC. BETWEEN FLOOR BLOCKS TO BE CONTINOUS 10) WRONG PLAN LEFT ON JOB SITE, DIDN'T CHECK SHEARWALLS LOCATION, H.D.'S 11) PLEASE CALL IN U-VALUE INSP 12) NAIL OFF OSB SHEAR LAUNDRY 13) STAPLE WAS THROUGH ROMEX REAR WALL FAMILY ROOM, MARKED ON FLOOR |