Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM00779
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/30/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER SUPER |
|
04/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED WIND BRACE NORTH WEST CORNER 1ST FLOOR 2) TOO MUCH NAILING MISSED, TOO MANY SHINNERS 3) ALL FRIEZE MISSED NAILS (SHINNERS) 4) WRONG NAILS IN SOME P.A. STRAPS 5) SHEAR PAGE 2ND FLOOR SHEAR TO LAP OUTSIDE WALL-SEE PLAN 6) AT 2ND FLOOR 1ST-2ND FLOOR STRAPS AT CORNERS OF SHEARWALL 7) STRAP COLUMN TO REAR PORCH BEAM 8) X BRACE TRUSSES WEST END OF VERT. MEMBERS 9) TWO BROKEN TRUSSES SEE MARK ON FLOOR 10) OSB AT FRONT COLUMN OR DBL STUD 11) MISSING HANGERS AT TRUSS TO GIRDER WORNG NAILS IN LOAD BEARING HANGERS |