Permit: T07CM00778

Parcel: 124020450


Addresses:

1621 E 1ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/30/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
CORRECTIONS MADE OK
PLUMBING FINAL OK
01/23/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
01/14/2008 PLUMBING - FINAL Not ready for Inspection 1. AT 3-COMP SINK: PROVIDE ACCESS TO DIELECTRIC UNIONS
PROVIDE APPROVAL FOR PEX IN LIEU OF COPPER TYPE "L"
TEST OK
OK TO COVER FLOOR AND WALL AT THIS AREA
2. HAND SINK OK
3. GAS CAPPED OK
4. INSTALL P-1 AT PREP SINK
5. WET VENTED SECTION TO BE 2"
6. PROVIDE DIELECTRIC PROTECTION AT WATER HEATER
SUPPORT EXPANSION TANK
01/10/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. NO CHANGE FROM LAST INSPECTION
2. CONTRACTOR TO PAY REINSPECTION FEE
01/09/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. CAP OFF GAS IN AN APPROVED MANNER AT RANGE DEMO
2. EXPOSE UNDER FLOOR WORK
3. TWO COMPARTMENTS OF 3-COMP SINK TO BE DIRECTLY CONNECTED TO SANITARY SEWER. 3RD COMPARTMENT (SANITIZING BOWL TO BE INDIRECTLY CONNECTED)
4. HAND SINK TO BE DIRECTLY CONNECTED TO SANITARY SEWER
5. COPPER TO BE SUPPORTED IN AN APPROVED MANNER
6. AT EXISTING FOOD PREP/HAND SINK UNDER CABINET PLUMBING NOT APPROVED