Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM00774
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/03/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
04/02/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL WATER CLOSETS BASE TO FLOOR 2) COMPLETE GROUNDING 3) PROVIDE ENERGY EFFICIENT 4) GAS CARD OK |
|
03/31/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR LIGHT FIXTURES NOT UNDER ROOF MUST BE SHIELDED 2) COMPLETE GRADING 3) POST HOUSE NUMBERS 4) LABEL CIRCUITS MAIN SERVICE PANEL 5) SEAL KNOCKOUT BOTTOM SERVICE PANEL 6) LABEL PLUMBING TYPE 7) SECURE GROUND #4 TO BLDG 8) PROVIDE ENERGY EFFICIENT CERT SERVICE PANEL 9) VACUUM BREAKERS HOSE BIBS 10) CONDENSORS OVER FUSED 11) SEAL WATER CLOSETS AT BASE 12) ARC FAULT PROTECT BEDROOM OUTLETS AND SMOKIES 13) WATER PROOF TRIM MASTER SHOWER CAN 14) PROVIDE ACCESS PANEL TO GFCI JACCUZI TUB MASTER 15) EXPOSED WIRING ENTRY, DINING ROOM 16) MISSING COVER PLATES THROUGHOUT 17) PROVIDE 30" DISCONNECTS FROM CONDENSORS |