| 08/24/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/22/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) TRUSS PROBLEMS 2) NEED CORRECT TRUSS DRAWINGS TRUSSES, A01 AND TRUSSES AT A/C OPENING 3) DON'T LOAD |
|
| 05/18/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED LARGER CRICKET AT GARAGE 2) TWO NAILS IN EACH WIND BRACE 3) STIFF BACK GABLE 4) CONTINOUS BEARING 5) TRUSS REPAIR DETAIL 6) NAIL/BLOCK OSB TURNED WRONG WAY GARAGE |
|
| 05/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BROKEN TRUSS LIV. ROOM - SEVERAL MEMBERS 2. TWO TRUSSES MISSING GUSSET PLATES 3. SECURE ENDS OF X BRACES 4. FINISH REAR PORCH 5. CLIP LARGE HEADERS & REAR PORCH BEAM 6. REAR PORCH LEDGER NOT NAILED TO ROOF DECK 7. WIND BRACE REAR WALL EAST 8. TWO NAILS EA. WIND BRACE AT BOT. PLATE 9. FRONT PL4 AT HIP TURNED WRONG WAY STOPPED INSPECTION DID NOT WALK ROOF |