Permit: T07CM00736

Parcel: 127080700


Addresses:

5410 E HOLMES ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/01/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/30/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED DBL KING STUDS AT SHEAR HOLDOWNS (2 PLACES)
2) NAILING OF OSB SHOULD BE MINIMUM 6" EDGES AND 12" IN FIELD UNLESS NOTED OTHERWISE
3) ON CONNECTION TO EXISTING BLDG 1 WOULD LIKE A MORE DETAIL CONNECTION, THAN WHAT IS THERE. TRUSSES HAVE 2 SEPERATE ELEVATIONS AT BOTTOM LID
4) ROOF OK TO DRY IN AND SHINGLE
5) NEED ANCHOR BOLTS 12" FROM END OF PLATES AND EACH SIDE OF SPLIT IN PLATES