Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/06/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) COMPLY WITH DETAIL 2/4 A34 2) ALL JACK TRUSSES AT GIRDER TRUSS 3) OK TO WRAP |
|
| 03/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING HANGERS ON DBL GIRDER TRUSSES PER DETAIL 2 ON ROOF PLAN 2) NEED DBL 2 X STUDS UNDER DBL GIRDER IN UNIT #1 3) CHECK ALL CLIP AND NAILING 4) NEED DBL 2 X STUD ON END OF SHEARWALL-AT ENTRY UNIT #2 5) OK TO DRY IN ROOF 6) FRAMING WILL BE INSPECTED AT INTERMEDIATES |