Permit: T07CM00717

Parcel: 14117007Q

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM00717

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/07/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
PIPE WRAPS, TRAP PRIMERS, FLOOR SINKS & DRAINS OK
WATER TEST URINAL OK
08/01/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- WATER TEST WASTE & VENT UNDERGROUND ALL AREAS EXCEPT P-4 MOP SINK & P3A URINAL OK
- GREASE WASTE FOR 3-COMP SINK & FLOOR SINK WATER TEST UNDERGROUND OK EXCEPT THAT P-12 FLOOR SINK SHALL MEET REQUIREMENTS FROM SECTION 1014.0, FLOOR MOUNTED FIXTURES HAVE NO CAPABILITY FOR FLOW CONTROL INSTALLATION TO A GREASE TRAP. PROVIDE A REVISED APPROVED PLAN TO ACCOMPLISH CORRECT INSTALLATION FOR GREASE WASTE SYSTEM.