Permit: T07CM00676

Parcel: 14043011A


Addresses:

7211 S PARK AV


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T07CM00676

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
05/11/2007 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
1) APPROVED AT 7'-4" CMU WALL TO TOP OUT
05/10/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
05/03/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NOTE: 48" A.F.F.E, 8X8X16 WITH #4 VERT. @ 16" O.C AND HORIZ. JOINT REINF. AT 16" O.C
04/26/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
24" A.F.F.E 2 COURSES OF CMU WALL, PRIOR TO GROUT PROVIDE CONTINUATION OF VERTICAL REINFORCING AND COMPLIANCE WITH THE MINIMUM OVERLAP IN ACCORDANCE WITH MSCJ AND DETAIL 9 ON SHEET S1.1 OR COMPLETE CMU TO TOPOUT AND CALL FOR REINFORCING MASONRY PRE-GROUT INSPECTION PRIOR TO GROUT.