Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T07CM00676
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/20/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* MASONRY ENCLOSURE WALLS IN COMPLIANCE WITH THE APPROVED PLANS REGARDING REBAR CONNECTIONS (EPOXY) TO EXISTING SLAB SPECIFIC DETAILS ON SHEET S1.1/E EPOXY CONNECTIONS/SPECIAL INSPECTION REPORT PROVIDED 01010 - STEMWALL/RETAINING WALL -- IN THIS SPECIFIC JOB THE INSPECTION RECORD CARD CALLS FOR 01010 INSPECTION WE USE THIS ITEM TO VERIFY BOND BEAM W/2 #4 CONT. ON THE FIRST COURSE OF CMU. MUST CALL FOR THE INSPECTION ABOVE MENTIONED ON THE FIRST LIFT OF CONCRETE MASONRY UNITS (CMU) |