Permit: T07CM00676

Parcel: 14043011A


Addresses:

7211 S PARK AV


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T07CM00676

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
04/20/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
MASONRY ENCLOSURE WALLS IN COMPLIANCE WITH THE APPROVED PLANS REGARDING REBAR CONNECTIONS (EPOXY) TO EXISTING SLAB SPECIFIC DETAILS ON SHEET S1.1/E

EPOXY CONNECTIONS/SPECIAL INSPECTION REPORT PROVIDED

01010 - STEMWALL/RETAINING WALL -- IN THIS SPECIFIC JOB THE INSPECTION RECORD CARD CALLS FOR 01010 INSPECTION WE USE THIS ITEM TO VERIFY BOND BEAM W/2 #4 CONT. ON THE FIRST COURSE OF CMU.

MUST CALL FOR THE INSPECTION ABOVE MENTIONED ON THE FIRST LIFT OF CONCRETE MASONRY UNITS (CMU)