Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T07CM00657
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/06/2007 | PLUMBING - GAS PRESSURE TEST | Approved | ||
05/21/2007 | PLUMBING - GAS PRESSURE TEST | Denied | 1. USE PRESSURE GAUGE WITH 1/10TH PSI INCREMENTATIONS 2. PRIME THEN WRAP ALL TOOL MARKS & FITTINGS 3. EXPOSE ALL FITTINGS 4. EXTEND PIPING FOR 700E TO METER IDENTIFIED AS 700E 5. PROVIDE 1" CLEARANCE BETWEEN WH VENT AND WOOD. 6. SECURE VENT CONNECTOR 7. T&P DRAIN CANNOT REDUCE, PROVIDE 3/4" WATER SUPPLY VALVE SAHLL BE FULLY PORTED AT WH. |
|
03/07/2007 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | POST ADDRESS IDENTIFY PIPING & METERS EXPOSE ALL NEW PIPING COMPLETE PIPING TO NEW UNITS HAVE NEW UNITS INSPECTED USE UNDAMAGED GAUGES THIS IS NOT A RECONNECT EXISTING PIPING IS STILL ATTACHED TO METER AND IS NOT UNDER TEST. NEW PIPING WHICH HAS BEEN PAINTED HAS A TEST GAUGE ON IT. |
|
02/28/2007 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BUILDING ADDRESS POSTED IS 1448 N 1ST AV 2. THIS DOES NOT MATCH ADDRESS ON PERMIT - PLEASE CORRECT 3. METERS ADDRESSED AS 700 AND 708 4. PRESSURE GAUGE READING ZERO 5. IDENTIFY WHICH PIPING SERVES WHICH BUILDING 6. WHICH BUILDING IS 699 E ADAMS? (T07PL00333) 7. PROVIDE ACCESS TO AND PERMITS FOR ALL NEW WORK I.E WATER HEATER, FURNACE, ETC. |
|
02/27/2007 | PLUMBING - GAS PRESSURE TEST | Cancelled | 390-0821 |