Permit: T07CM00650

Parcel: 140430130

Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T07CM00650

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
11/26/2008 SITE - SEWER Approved IVRS - Inspection :*
12/20/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
1. PROVIDE VERIFICATION OF GRADE
2. BENCH IN MANHOLE OK
10/02/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
AIR TEST FROM MANHOLE TO STUBS 5' FROM BUILDINGS OK
09/28/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
6" SDR 35 CONTINUOUS TO MAINTENANCE BLD 5' AND
4" SDR 35 CONTINUES TO WAREHOUSE BLD 5'
AIR TEST & VERIFICATION OF GRADE AT LATER DATE
09/27/2007 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
09/26/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
PIPING TO CLEANOUT LOCATION ON EAST SIDE OF STREET OK
09/25/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
6" SDR 35 FROM EXISTING MANHOLE (1) CLEANOUT INSTALLED APP. 40 FROM MANHOLE, PIPING APP. 80' GOING EAST, BEDDING, LAYING, SHADING, TRACER WIRE. SHALL PROVIDE LETTER GIVING OK FOR SDR 35 IN PLACE OF PVC SCH 40 STAMPED BY ENGINEER, AIR TESTING & VERIFICATION OF GRADE BY ENGINEER OR LICENSED SURVEYOR AT LATER DATE