Permit: T07CM00626

Parcel: 128100560

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07CM00626

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/21/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/19/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ALL SWITCHES NEED TO BE PROPERLY GROUNDED
2. #14 GAUGE WIRE USE FOR LIGHTING SWITCH LEG
ON 20A #12 GAUGE CIRCUIT
3. CANNOT STAB #12 GAUGE WIRE INTO BACK OF SWITCHES
03/08/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
NEED TO VERIFY ALL SWITCHES AS BEING GROUNDED AND POLARIZATION & GROUNDING OR RECEPTACLES
MOVE FURNITURE TO CHECK RECEPTACLES
INSPECT CEILING ONCE FOR WIRING.