Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/19/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ALL SWITCHES NEED TO BE PROPERLY GROUNDED 2. #14 GAUGE WIRE USE FOR LIGHTING SWITCH LEG ON 20A #12 GAUGE CIRCUIT 3. CANNOT STAB #12 GAUGE WIRE INTO BACK OF SWITCHES |
|
| 03/08/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* NEED TO VERIFY ALL SWITCHES AS BEING GROUNDED AND POLARIZATION & GROUNDING OR RECEPTACLES MOVE FURNITURE TO CHECK RECEPTACLES INSPECT CEILING ONCE FOR WIRING. |