Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/23/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA STRAP OVER BORE AT H20 MAIN RISER AND DRYER VENT. DRYER VENT NEEDS FHA STRAP NOT COIL |
|
| 05/18/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA STRAP OVER BORE AT H20 MAIN RISER AND DRYER VENT-DRYER VENT NEEDS FHA STRAP NOT COIL 2) NEED 1" TO WOOD AT H20 HEATER FLUE 3) NEED DWV TEST 4) FIRE CAULK FURRED TOP PLATES 5) BLOCK DUCT BOOTS 3 SIDES 6) BANG PLATE HOMERUNS 7) SEAL ALL DUCT INSULATION |
|
| 04/06/2007 | FRAMING | Not ready for Inspection | CALL FOR AFTER INTERMEDIATES |